3017 S. County Line Road, Plant City, FL 33566
Property Overview
County Line Crossing offers a spacious and versatile layout, with a total area of ±535,507 SF that is divisible to ±300,000 SF.
The building features a substantial clear height of 36 feet, facilitating efficient vertical racking. The 185-foot deep truck court ensures smooth logistics and maneuverability. The facility includes 98 dock-high loading doors and 4 oversized drive-in ramps to accommodate various loading and unloading needs. With 301 auto parking spaces and 208 trailer parking spaces, this property is designed to support extensive warehousing and distribution operations. County Line Crossing is strategically situated on County Line Road, just 1.5 miles south of the I-4 interchange, at the border of Hillsborough and Polk Counties. The I-4 Corridor location is renowned for its logistical advantages and is home to major distribution centers for companies such as Amazon, Publix, Home Depot, and O’Reilly’s, among others.
Site Plan
Site Area
42.62 acres
Building Area
±535,539 SF measured to drip line, excluding attached canopies
Building Dimensions
550’ D x 972’ L
Clear Height
36’ minimum clear height at bottom of bar joist at first bay-in from truck dock
Column Spacing
54’ wide x 53’-9” deep typical with 60’ deep spacing in staging bays
Spec Office
±2,466 SF spec office with breakroom, (2) office restrooms and (2) warehouse restrooms
Fire Protection System
ESFR system, with K-22.4 sprinkler heads at 40 psi
Fire Alarm
System monitored for tamper and flow.
Automobile Parking
(301) parking spaces available
Trailer Parking
(208) trailer spaces available
Truck Court
North side: 185’ Truck Court. South Side: 135’ Truck Court, 7” thick 4,000 psi concrete truck apron and dolly strips, heavy duty asphalt in drives and remainder of truck courts, standard duty asphalt in auto parking lots.
Building Floor
7” reinforced concrete slab in speed bays with #3 rebar 16” OCEW, 4,000 psi, vapor barrier for entire slab
Electrical
3000A, 480V, 3P
Interior Lighting
LED warehouse lighting at 25FC
Exterior Lighting
LED walls packs and light poles
Truck Doors
(98) 9’ x 10’ dock doors (12 with mechanical levelers & bumpers)
Drive-In Ramp Door
(4) drive in ramps with a 12’ x 14’ door
Personnel Doors
Fire department access doors are installed per code.
Air Changes
Includes ventilation fans and louvers; total louver capacity of 0.52 air changes per hour under general ventilation conditions.
Roof
45 Mil TPO single-ply white membrane mechanically fastened with:
- Slope ½ ” per foot
- R-19 Rigid Insulation – one (1) layer of 2.6 insulation
- Exterior gutters and downspouts
- 15-year NDL warranty
Roof Structure
Metal deck supported by structural steel, conventional joist and girders
ADA
All improvements are designed and constructed per ADA accessibility guidelines
Site Area
42.62 acres
Column Spacing
2,507 SF spec office with breakroom, (2) office restrooms and (2) warehouse restrooms
Building Area
535,539 SF measured to drip line, excluding attached canopies
Building Dimensions
550’ D x 972’ L
Clear Height
36’ minimum clear height at bottom of bar joist at first bay-in from truck dock
Spec Office
54’ wide x 53’-9” deep typical with 60’ deep spacing in staging bays
Fire Protection System
ESFR system, with K-22.4 sprinkler heads at 40 psi
Fire Alarm
System monitored for tamper and flow.
Automobile Parking
(301) parking spaces available
Trailer Parking
(208) trailer spaces available
Truck Court
North side: 185’ Truck Court. South Side: 135’ Truck Court, 7” thick 4,000 psi concrete truck apron and dolly strips, heavy duty asphalt in drives and remainder of truck courts, standard duty asphalt in auto parking lots.
Building Floor
Slab 7” reinforced concrete slab in speed bays with #3 rebar 16” OCEW, 4,000 psi Vapor barrier for entire slab
Electrical
3000A, 480V, 3P
Interior Lighting
LED warehouse lighting at 25FC
Exterior Lighting
LED walls packs and light poles
Truck Doors
(98) 9’ x 10’ dock doors (12 with mechanical levelers & bumpers)
Drive-In Ramp Door
(4) drive in ramps with a 12’ x 14’ door
Personnel Doors
Fire department access doors are installed per code.
Air Changes
Includes ventilation fans and louvers; total louver capacity of 0.52 air changes per hour under general ventilation conditions.
Roof
45 Mil TPO single-ply white membrane mechanically fastened with:
- Slope ½ ” per foot
- R-19 Rigid Insulation – one (1) layer of 2.6 insulation
- Exterior gutters and downspouts
- 15-year NDL warranty
Roof Structure
Metal deck supported by structural steel, conventional joist and girders
ADA